1. Introduction
AuruMEX PG-9600 is a mildly acidic gold plating product specially designed to produce 99.99% pure gold deposits for transistors, integrated circuits, and other semiconductor components.
AuruMEX PG-9600 combines excellent solderability with a fine‑grained, cohesive structure that exhibits superior workability characteristics. The stability of the AuruMEX PG‑9600 plating bath maintains high purity levels under practical plating conditions.
AuruMEX PG‑9600 deposits offer corrosion resistance and tarnish resistance, with a contact resistance of 0.3 mΩ. The process is suitable for both rack and barrel electroplating.
AuruMEX PG‑9600 is a mildly acidic, high‑purity gold electroplating process that produces matte to semi‑bright, ultra‑pure, and ductile gold coatings. These deposits comply with the requirements of Type III, Code A under ASTM B488‑11 (superseding U.S. Military Specification MIL‑G‑45204).
2. Physical Properties
Parameter | Optimum Value |
Purity (%) | 99.99 |
Hardness (Knoop) | 50 to 80 |
Contact Resistance (mΩ) | 0.3 |
Deposit Weight per 1 μm Thickness (mg/cm2) | 1.92 |
Efficiency (mg/A·min) | 115 (110 to 120) |
Plating Rate (min/μm) (at 0.4 A/dm2) | 4 |
3. Solution Composition
AuruMEX PG‑9600B MakeUp is supplied as a liquid concentrate. Each unit (3 liters) contains all the components required to prepare 5 liters of plating bath. It does not contain gold.
4. Solution Preparation (to make 10 liters)
1. The plating tank should be thoroughly cleaned and filled with 2 liters of deionized or distilled water.
2. Heat the water above, and add 2 units of AuruMEX PG‑9600B MakeUp in the temperature range of 50 to 60°C while stirring.
3. Add 117.6 g of gold salt in the form of potassium gold cyanide containing over 68% gold content, which has been previously dissolved in hot deionized or distilled water (at a gold metal concentration of approximately 100 g/L).
4. Fill up to 10 liters with deionized or distilled water.
5. Check and adjust the pH if necessary. The solution is then ready for use.
5. Equipment
● Tank: Tanks lined with Pyrex, PTFE, polypropylene, PVDC, or high‑density polyethylene (HDPE) should be used. Metal tanks are not recommended, as they will be attacked during the electrolysis process and cause contamination.
● Rectifier: A DC power supply with a ripple of less than 5% should be used, with an ampere output capacity sufficient to meet the requirements of the electroplating operation. The power supply should be equipped with a voltmeter, an ammeter, and stepless controls for precise current adjustment. The use of an ampere‑minute meter (amp‑hour/amp‑minute counter) is recommended.
● Filtration: The solution should be continuously filtered through polypropylene or cotton filter cartridges to maintain clarity.
● Agitation: Moderate to vigorous agitation is necessary to maintain uniform metal distribution.
● Temperature Control: The temperature should be maintained between 50 and 70°C. Immersion heaters or external stainless steel (Type 316) heat exchangers may be used. Do not use quartz elements.
● Anodes: Insoluble anodes should be used with this solution. Platinized titanium anodes or platinum anodes are recommended, with an area sufficient to provide an anode‑to‑cathode ratio of 4:1 or higher.
6. Operating Parameters
Operating Parameter | Range | Optimum Value |
Gold Metal Content | 6 to 10 g/L | 8 g/L |
Temperature | 50 to 70°C | 65°C |
pH at 25°C | 4.5 to 5.0 | 4.75 |
Specific Gravity at 25°C | 13 to 20°Baumé | 16°Baumé |
Current Density | 0.2 to 1.0 A/dm2 | 0.4 A/dm2 |
7. Bath Maintenance
Maintain the gold metal content within the recommended concentration range (6 to 10 g/L) by periodically adding potassium gold cyanide (with over 68% gold content) previously dissolved in hot deionized or distilled water at a concentration of approximately 100 g/L gold metal.
AuruMEX PG‑9600REP Replenisher R is supplied as a liquid concentrate in 200 mL units. Each unit contains all the necessary reagents for addition alongside the appropriate amount of gold salt, equivalent to 100 g of gold metal.
For every 1 g of gold metal consumed, 1.47 g of potassium gold cyanide and 2 mL of AuruMEX PG‑9600REP Replenisher R must be added. Frequent, regular additions are recommended to maintain the plating bath at its optimal concentration.
8. Product Information
Product | Specification |
AuruMEX PG‑9600B Make Up | Make Up B, 3 L |
AuruMEX PG‑9600 REP | Replenisher R, 200 mL |
AuruMEX PG‑9600 Conducting Salt | Conducting Salt, 1 kg |
AuruMEX PG‑9600 Grain Refiner | Grain Refiner, 200 mL |
AuruMEX PG‑9600 Acid Adjusting Salt | Acid Adjusting Salt, 1 kg |
Gold Consumption
Under optimum operating conditions, the AuruMEX PG‑9600 process deposits metal at the following rates:
Ampere‑Minutes (A⋅min) | Gold Deposited |
1000 | 110 g |
909 | 100 g |
Because drag‑out losses cannot be calculated precisely, periodic analytical checks should be performed to confirm amp‑minute meter readings.
pH Adjustment
To maintain the pH value between 4.5 and 5.0, proceed as follows:
● To lower the pH: Add AuruMEX PG‑9600 Acid Adjusting Salt.
● To raise the pH: Add a 20% chemically pure potassium hydroxide (KOH) solution.
Conductivity
The specific gravity of the solution should be maintained between 13°Baumé and 20°Baumé. If, due to excessive drag‑out, the specific gravity drops below 13°Baumé, AuruMEX PG‑9600 Conducting Salt should be added to raise the specific gravity back to at least 13°Baumé.
Impurity Control
Metallic Impurities: Metallic contamination can interfere with the operation of the AuruMEX PG‑9600 bath. To prevent this, parts to be plated and any gold strike layers must be thoroughly rinsed prior to gold electroplating.
9. Waste Disposal
Before applying any waste disposal recommendations or suggestions, users must understand the appropriate local regulations governing on‑site or off‑site treatment, which may require specific permits. In the event of any conflict between our recommendations and local regulations, local regulations shall prevail.
10. Disclaimer
All suggestions or recommendations regarding our products contained in this technical data sheet are based on experiments and data believed to be reliable by our company. Since actual operations by third parties are beyond our control, our company guarantees no performance outcomes and accepts no liability for any adverse results. Nothing in this document shall be construed as evidence of or authorization for patent or copyright infringement.